Standard sensor housing
- IP41 rated
- For applications in normal conditions and in facilities with low levels of dust or moisture
- Typically used in plant rooms, machinery rooms and cold rooms
- Semiconductor model can be used in -20°C to +50°C.
- Infrared models can be used in 0°C to +50°C
|
|
IP66 sensor housing
- IP66 rated
- For applications where high levels of dust, moisture or condensation are present.
- Fitted with Delrin head preventing condensation within the electronics
- Fast response
- Semiconductor model can be used in -40°C to +50°C
- Electrochemical model can be used in -40°C to +40°C
- Not available for IR CO2 sensors
|
|
IP55/Low Temp sensor housing
- IP55 rated
- For applications where dust or moisture (non condensing) is present. (Breather drain must point downwards)
- Typical applications include: cold stores, swimming pools, outdoor areas, marine industry and food processing plants
- For applications down to -40 °C
- Can also be used for Carbon Dioxide low temperature applications (to –40 °C) using an heater circuit
- Standard Entries – 20mm ISO metric
|
|
Decorative Face Plate (For Remote Sensor)
- For installations where aesthetics are important
- Brushed stainless steel, discrete low profile remote sensor and facia, can be mounted within a single gang electrical wall box (min 47mm deep)
- Wires directly into the controllers sensor connection
- Requires a controller that supports a remote sensor.
- Provided with 10 metres of fly-lead cable
- Alternative fascias can be supplied to special order to match decor
|
|
Airflow / Duct Mount Indoor
- Monitor internal airflows or ducts while allowing easy access to the sensor for maintenance.
- Uses pitot type sample tubes to extend into the duct.
- Used to monitor leaks in air conditioning or a gas in an airflow.
|
|
Airflow / Duct Mount Outdoor
- Monitor external airflows or ducts while allowing easy access to the sensor for maintenance.
- Uses pitot type sample tubes to extend into the duct.
- Used to monitor leaks in air conditioning or a gas in an airflow.
|
|
EExd - hazardous areas
- ATEX standard Exd rated enclosure
- For use in hazardous areas, where flammable gases, vapour fumes or dust are present.
- Typical applications include hazardous areas such as machinery rooms, boiler rooms, storage facilities, and refrigeration.
- Approved for Zone 1 and Zone 2. Flameproof, explosion proof, and weatherproof (ATEX, Ex d IIB+H2 T6 IP66).
- Standard Entries: 20 I.S.O metric, 1.5mm pitch
|
|
Vent Pipe Indoor
- Used to monitor any weeping gases from internal pressure relief valves or similar gas leaks in normal pressure pipes or gas levels in airflows in pipes.
- Sensor head is fitted into a threaded gun-barrel fitting 1” BSP (brass option shown).
- The fitting screws into a tee on the vent pipe 1-2m above the pressure relief valve.
|
|
Vent Pipe Outdoor
- Used to monitor any weeping gases from external pressure relief valves or similar gas leaks in normal pressure pipes or gas levels in airflows in pipes.
- Sensor head is fitted into a threaded gun-barrel fitting 1” BSP (brass option shown).
- The fitting screws into a tee on the vent pipe 1-2m above the pressure relief valve.
|
|
Remote EExd sensor head – IP66 Housing
- ATEX approved Exd
- For use in hazardous areas, where flammable gases, vapor fumes or dust are present
- Economical alternative to the Exd enclosure
- Exd remote senor head is located in the Ex area and is connected by a 5 meter cable to the enclosure outside the hazardous area e.g. a standard, IP66, or other
- Approved for Zone 1 and Zone 2. Ex d IIB+H2 T6
- Typical applications include areas classified as hazardous such as machinery rooms, boiler rooms, storage facilities, and refrigerated areas
|
|
Remote sensor head – IP66 Housing
- Remote sensor contained within a Delrin head to prevent condensation reaching the electronics
- Fast response
- Rated –40 °C to +50 °C. (+40 °C with electrochemical sensors)
- The IP66 enclosure is recommended for applications where high levels of dust, moisture or condensation are present.
|